Aura2 – stand-alone ambient sensor module

Aura2 · Ambient sensor module

Day and night, on record

Stand-alone logging of temperature, humidity and pressure

Temperature, humidity and barometric pressure where you weigh and measure, every value with its standard deviation and number of readings.

Coming early 2027

Calibration

Traceable to the SI

Supplied uncalibrated as standard, with calibration as an option: by Qualimetric in accordance with ISO/IEC 17025, or by a calibration laboratory of your choice. A unique hardware identity links every reading to its certificate.

Logging

Logs on its own

Every 60 seconds, or anything from 5 seconds to 24 hours, to a microSD card: also on battery, also without a computer. Read measurements and log files from a browser over Wi-Fi; settings change over USB only.

Statistics

Every value with its spread

Each value is the average of a series of independent readings, 16 by default and up to 200, reported with its standard deviation and number of readings: ready for a type A uncertainty evaluation. No smoothing, no filters.

Weighing

Air-buoyancy correction

Temperature, humidity and pressure at the moment of weighing, for the air density and the correction to the mass.

Quality

ISO/IEC 17025 records

Ambient conditions monitored and recorded where they influence your results, day and night.

Independent

Stand-alone and secure

No cloud, no account, no app that has to stay online. Wireless access is read-only.

Environmental log

A day on record

Temperature from the log of an Aura2 on 3 October 2026: one value per minute, each the mean of 16 readings with its standard deviation. On the right, half an hour enlarged.

Data access

Read it your way

No app to install. Open the address of the Aura2 in a browser on the same network and it answers with the measurement as JSON: the mean of 16 readings with its standard deviation. Or read it from your own software in a few lines of Python, with nothing but the standard library. Both are real: an Aura2 on our network, on 8 October 2026.

Preventive service

We recommend a preventive service every two years, at additional cost: new battery and clock cell, the current firmware if you wish, and a full function test. Combined with a calibration, the unit is calibrated as found and as left, keeping your measurement history continuous.

Front, back and inside

Aura2, front
Aura2, back
Aura2, inside

Specifications

Aura2
Temperature0 – 50 °C
Relative humidity0 – 95 %RH, non-condensing
Barometric pressure30 – 125 kPa
Calibration (optional)by Qualimetric in accordance with ISO/IEC 17025, or by a calibration laboratory of your choice
Calibration range (optional)10 – 30 °C · 20 – 85 %RH · 80 – 120 kPa (Qualimetric calibration; accredited calibration range on request)
Outputmean, SD and n per quantity; pressure in Pa
Averaging1 – 200 readings per measurement
InterfaceUSB-C; Wi-Fi 2.4 GHz (read-only HTTP/JSON)
Data access (API)REST API over Wi-Fi for measurements and log files (JSON, logs as CSV), discoverable on the network; JSON protocol with CRC-32 over USB. See the API manual (PDF)
Environmental logmicroSD, CSV, one file per day (UTC), interval 5 s – 24 h
Real-time clockwith backup cell; set from computer or time server
Power5 V DC via USB-C; Li-Po 3.7 V
Enclosure150 × 82 × 30 mm
Operating conditionsindoor, 0 – 50 °C, 0 – 95 %RH non-condensing; charging 0 – 45 °C
Softwarebrowser access over Wi-Fi; documented API over USB and Wi-Fi for your own software

Not for safety-critical or life-support applications. The environmental log is indicative; use requested measurements for calibration records.

Coming early 2027

Register your interest to be kept informed of the release, or tell us about your balance room and software so we can advise on its use.

Descriptions reflect the products as they are being developed and may change before release. See our disclaimer.