Aura · Ambient sensors
Measured air
The air your laboratory breathes in
Temperature, humidity and barometric pressure where you weigh and measure, every value with its standard deviation and number of readings. Two models, one way of measuring.
Coming early 2027

Measured, not assumed
Gravimetric work needs to know the air it weighs in. The Aura sensors measure that air instead of assuming it, and report the spread of their readings: each value is the average of a series of independent readings, ready for a type A uncertainty evaluation.
Aura1
Made for the balance
Compact and powered over USB, without battery or radio: the computer reads it directly. Designed for the gravimetric preparation of calibration gases, and the recommended companion of GasCatena, which reads it at every weighing.


Aura2
On its own, day and night
Battery-backed, logging to a microSD card every minute, also without a computer. Read over USB or from a browser over Wi-Fi, with calibration traceable to the SI as an option. For balance rooms and laboratories that want ambient conditions on record around the clock.
Compare the models
| Aura1 | Aura2 | |
|---|---|---|
| Measures | Temperature, relative humidity, barometric pressure | |
| Sensors | Digital MEMS sensors for temperature and humidity and for barometric pressure | |
| Temperature | 0 – 50 °C | |
| Relative humidity | 0 – 95 %RH, non-condensing | |
| Barometric pressure | 30 – 125 kPa | |
| Output | mean, SD and n per quantity; pressure in Pa | |
| Readings | taken by the host computer, 16 by default | taken by the module itself, 1 – 200 per measurement |
| Interface | USB-C, standard USB device (HID), no driver needed | USB-C; Wi-Fi 2.4 GHz (read-only) |
| Environmental log | none; the host software keeps the record | microSD, one file per day |
| Clock | none; the host computer stamps each value | real-time clock with backup cell |
| Power | 5 V DC via USB-C | 5 V DC via USB-C; Li-Po battery |
| Calibration (optional) | by Qualimetric in accordance with ISO/IEC 17025, or by a calibration laboratory of your choice | |
| Enclosure | 86 × 85 × 25.5 mm | 150 × 82 × 30 mm |
| Best for | at the balance, read by GasCatena at every weighing | monitoring on its own, day and night |
Weighing
Air-buoyancy correction
Temperature, humidity and pressure at the moment of weighing, for the air density and the correction to the mass.
Quality
ISO/IEC 17025 records
Ambient conditions monitored and recorded where they influence your results.
Independent
Stand-alone and secure
No cloud, no account, no app that has to stay online.
Influence quantities
What it is, and why it matters
“Quantity that, in a direct measurement, does not affect the quantity that is actually measured, but affects the relation between the indication and the measurement result.”
International Vocabulary of Metrology (VIM), JCGM 200:2012, 2.52
Temperature, pressure and humidity are influence quantities: they change the air density, and with it the buoyancy on a cylinder on the balance, and they move instruments. The Aura sensors measure them where you weigh and measure, with mean and spread per reading.
Coming early 2027
Register your interest to be kept informed of the release, or tell us about your balance room and software so we can advise on the right model.
Descriptions reflect the products as they are being developed and may change before release. See our disclaimer.