GasCatena – gravimetric gas preparation

GasCatena · Gravimetric gas preparation

An unbroken chain

From weighing to traceable calibration gases

Guided gravimetric preparation of calibration gas mixtures according to ISO 6142-1, alongside the analytical balance you already have.

Coming early 2027

Metrological traceability

What it is, and why it matters

“Property of a measurement result whereby the result can be related to a reference through a documented unbroken chain of calibrations, each contributing to the measurement uncertainty.”
International Vocabulary of Metrology (VIM), JCGM 200:2012, 2.41

Catena is Latin for chain. A calibration gas is only as good as the chain behind it, and GasCatena documents every link of that chain for a gravimetric preparation: the calibrated balance, the purity of the base gases from their certificates, the molar masses and the air at the balance, each with its stated uncertainty, through to the certificate. So your laboratory can show where every value comes from.

1. Recipetarget composition,order and dilutions2. Guided weighingyour balance, airdata from the Aura13. Compositionmole fractions, u(y),covariance (GUM)4. Verificationindependent analysis(ISO 6143), Eₙ test5. Scope checkagainst the CMC ofyour accreditation6. CertificatePDF andISO 23219 XML

Plan

Mixtures planned before you weigh

A register of recipes; the addition order follows the vapour pressure, pre-mixtures are flagged, and the expected uncertainty is known before you start.

Weigh

Fewer errors at the balance

Target pressures and expected readings at every step. Unstable or wrong-direction weighings are rejected on the spot, with a cooling wait after large pressure steps.

Certify

A certificate you can defend

Mole fractions, uncertainties and covariance according to ISO 6142-1, ISO 14912 and the GUM, checked against your scope and issued as PDF and ISO 23219 XML.

Verified before certified

Every prepared mixture can be compared with an independent analysis of the same cylinder and judged with the En test. NexChrom provides that analysis on your GC: errors-in-variables regression following ISO 6143 against certified reference gases, with GUM uncertainty on every mole fraction.

The Aura1 ambient sensor

Highly recommended · Aura1

The air at the balance, on record

At every weighing GasCatena reads the Aura1 next to the balance: temperature, humidity and pressure give the air density and the buoyancy effect, shown and reported with the preparation. The Aura1 was designed for exactly this task: compact, powered over USB and read directly by GasCatena.

Independent

Stand-alone and secure

GasCatena runs as a local service and is used in a web browser, fully offline, without a cloud account. Your preparations and certificates stay in your own laboratory.

Accreditation

Built for accredited laboratories

For laboratories and reference material producers working to ISO/IEC 17025 and ISO 17034, with every result checked against the scope of your accreditation.

Data

Your systems, your data

Registers for base gases, balances and cylinders with their certificates and due dates. Certificates as PDF and as ISO 23219 XML.

Standards

The standards and guidance GasCatena is built on.

Coming early 2027

Register your interest to be kept informed of the release of GasCatena, or request a preview of a preparation from recipe to certificate.

Descriptions reflect the products as they are being developed and may change before release. See our disclaimer.