GasCatena – gravimetric gas preparation

GasCatena · Gravimetric gas preparation

An unbroken chain

From weighing to traceable calibration gases

Guided gravimetric preparation of calibration gas mixtures according to ISO 6142-1, alongside the analytical balance you already have.

Coming early 2027

Where does every value come from?

A calibration gas is only as good as the chain behind it. GasCatena keeps every link on record.

1. Recipetarget composition,order and dilutions2. Guided weighingstep by step atyour own balance3. Compositionmole fractions, u(y),covariance (GUM)4. Verificationindependent analysis(ISO 6143), Eₙ test5. Scope checkevery componenttested against the CMC6. CertificatePDF andISO 23219 XML

Plan

Mixtures planned before you weigh

A register of recipes; the addition order follows the vapour pressure, pre-mixtures are flagged, and the expected uncertainty is known before you start.

Weigh

Fewer errors at the balance

Target pressures and expected readings at every step. Unstable or wrong-direction weighings are rejected on the spot, with a cooling wait after large pressure steps.

Verify

Checked against an independent analysis

Every prepared mixture can be compared with an independent analysis of the same cylinder and judged per component with the En test: verified before it is certified.

Certify

A certificate you can defend

Mole fractions, uncertainties and covariance according to ISO 6142-1, ISO 14912 and the GUM, checked against your scope and issued as PDF and ISO 23219 XML.

GasCatena: ISO 6976 propertiesGasCatena: Ambient log: temperatureGasCatena: Scope of accreditation checkGasCatena: Guided weighing: balance readoutGasCatena: Filling steps: target pressure per stepGasCatena: Verification: En testGasCatena: Certificate: ambient conditions per weighingGasCatena: Certificate: traceability and weighings

Recipe

The uncertainty, before you weigh

For the balance, cylinder and filling pressure you choose, GasCatena estimates the expanded uncertainty of every component before the first weighing. You know whether the mixture is feasible before you start.

Guided weighing

Step by step at the balance

Each addition comes with its target pressure and expected weight. A weighing is accepted only when the readings are stable and the weight moves in the right direction.

Verification

Verified with the En test

The independent analysis of the same cylinder next to the gravimetric values, judged per component with the En test. Verified before certified.

Worklist

The day’s work as piles of cards

Cylinders due for retest, balances without a valid calibration, parent gases near their shelf-life date, preparations to finish and gases still to verify: the worklist lays them out as piles of cards, by urgency and by process step. One click opens a card, with why it matters and what to do.

Independent

Stand-alone and secure

GasCatena runs as a local service and is used in a web browser, fully offline, without a cloud account. Your preparations and certificates stay in your own laboratory.

Accreditation

Built for accredited laboratories

For laboratories and reference material producers working to ISO/IEC 17025 and ISO 17034, with every result checked against the scope of your accreditation.

Data

Your systems, your data

Registers for base gases, balances and cylinders with their certificates and due dates. Certificates as PDF and as ISO 23219 XML.

Better together

NexChrom verifies the gases GasCatena prepares, and the Aura1 records the air at the balance.

NexChrom

Verified before certified

Every prepared mixture can be compared with an independent analysis of the same cylinder and judged with the En test. NexChrom provides that analysis on your GC: errors-in-variables regression in conformity with ISO 6143 against certified reference gases, with GUM uncertainty on every mole fraction.

NexChrom
The Aura1 ambient sensor

Highly recommended · Aura1

The air at the balance, on record

At every weighing GasCatena reads the Aura1 next to the balance: temperature, humidity and pressure give the air density and the buoyancy effect, shown and reported with the preparation. The Aura1 was designed for exactly this task: compact, powered over USB and read directly by GasCatena.

Metrological traceability

What it is, and why it matters

“Property of a measurement result whereby the result can be related to a reference through a documented unbroken chain of calibrations, each contributing to the measurement uncertainty.”
International Vocabulary of Metrology (VIM), JCGM 200:2012, 2.41

Standards

The standards behind every screen, every procedure and every document in GasCatena, from the gravimetric preparation to verification, the certificate and the quality system. Click one for the official text.

Coming early 2027

Register your interest to be kept informed of the release of GasCatena, or request a preview of a preparation from recipe to certificate.

Descriptions reflect the products as they are being developed and may change before release. See our disclaimer.