NexChrom · GC software for natural gas

Certified gas analysis

From sample to certificate

One application for the complete GC workflow. Every result comes with its uncertainty, its calibration and the person who approved it.

Coming early 2027 · pilot laboratories welcome

How do you know?

A certificate says 86.0 %. NexChrom says why, with the proof on record.

Step 1

From CDS file

Peak tables straight from your chromatography data system, natively or via export. Every file is stored with its hash.

Step 2

To calibrated result

Errors-in-variables regression following ISO 6143, and GUM uncertainty on every mole fraction. No spreadsheets, no copied numbers.

Step 3

To validated result

Automatic checks before anyone signs: QC samples against Westgard rules, results outside the calibrated range flagged. A failed QC run cannot be approved.

Step 4

To certificate

A second person approves every run before release. The certificate is frozen as a PDF, with everything behind it on record.

NexChrom: CertificatesNexChrom: Quality controlNexChrom: Regression results: nitrogenNexChrom: Calibration curve: methaneNexChrom: Residuals: methaneNexChrom: Calibration curve: nitrogen (EIV, order 2)NexChrom: Residuals: nitrogen (EIV)

Calibration

Calibration you can defend

Errors-in-variables regression following ISO 6143, or OLS, WOLS and GLM. Every fit with its statistics, every replicate screened for outliers, every model versioned and never overwritten.

Uncertainty

Uncertainty on every result

Every mole fraction comes with its expanded uncertainty, propagated according to the GUM from the calibration and the replicates. Results outside the calibrated range are flagged.

Quality control

Nothing released without a second look

QC samples on control charts with automatic checks. A failed QC run cannot be approved, and a second person releases every run, calibration model and certificate.

Dashboard

Quality indicators at a glance

One screen for the daily check: runs waiting for review, failed QC runs in the last 30 days, certificates and calibrations due or overdue, alerts by severity and a status light per instrument.

Certificates

Every certificate on record

Analysis certificates frozen as PDF. Reference certificates imported from PDF and checked against the source at approval, with their validity and cylinder in view.

Independent

Stand-alone and secure

Runs in your own laboratory, with your data in a local database. No cloud account, no outside service it depends on.

Accreditation

Validation documentation

Calculation specification, validation reports, test plans and test reports, for the validation of NexChrom in your accredited laboratory.

Data

Your systems, your data

Peak tables from your data system, natively or via export. Results and master data export as CSV, certificates as PDF.

Better together

NexChrom verifies the calibration gases from GasCatena, and the Aura sensors record the air it measures in.

GasCatena

Verifying calibration gases

Prepare your own calibration gas mixtures by weighing? GasCatena guides the gravimetric preparation; NexChrom provides the independent analysis that verifies it: the cylinder analysed against certified reference gases, with its GUM uncertainty, for the En test in GasCatena.

GasCatena
The Aura1 and the Aura2 ambient sensors

Aura

The air your laboratory breathes in

Temperature, humidity and barometric pressure where you weigh and measure, every value with its spread: for air-buoyancy, pressure and temperature corrections and for your ISO/IEC 17025 records.

Measurement uncertainty

What it is, and why it matters

“Non-negative parameter characterizing the dispersion of the quantity values being attributed to a measurand, based on the information used.”
International Vocabulary of Metrology (VIM), JCGM 200:2012, 2.26

A mole fraction without its uncertainty is just a number. With it, a result can be compared with a specification, with another laboratory or with a certified reference gas, and defended in front of an assessor. NexChrom propagates the uncertainty according to the GUM from the calibration and the replicates, for every component in every run.

Standards

The standards behind every screen, every procedure and every document in NexChrom, from the analysis of natural gas to calibration, uncertainty and the quality system. Click one for the official text.

Coming early 2027

See NexChrom with your own data. Laboratories are welcome to request a preview or to take part as a pilot laboratory.

Descriptions reflect the products as they are being developed and may change before release. See our disclaimer.