News – NexChrom, GasCatena and Aura

News

News

What is new at Qualimetric

New products, releases and what is being worked on.

21 October 2026 · Research note

Two axes, two kinds of uncertainty

Three to five replicates per level are too few to say how uncertain a response is, yet errors-in-variables calibration weights every point with exactly that number. A new research note by Erik van der Werff treats the two axes differently: the reference uncertainties as stated per material, the scatter of the response as one variance function estimated from all replicates together. The method and the design of its evaluation are set out; the simulation study and an application to real data are planned.

12 October 2026 · White paper

Not rejected ≠ proven

A result that has merely not been rejected is often reported as if it had been proven. A new white paper by Erik van der Werff shows where that happens in conformity decisions, method comparison, calibration and analyser evaluation in gas analysis, with worked numbers, and how a report can keep the undecided zone visible.

7 October 2026 · Software

Introducing GasCatena

Besides NexChrom, a complementary software product: GasCatena guides laboratories through the gravimetric preparation of calibration gas mixtures, from recipe and weighing to a certificate with GUM uncertainty, and documents every link of the traceability chain. Catena is Latin for chain.

GasCatena logo

5 October 2026 · Software

NexChrom in pictures: a tour in sixteen screens

How NexChrom looks in daily use: CDS data straight from the instrument, calibration with residuals, mole fractions with their uncertainty, release by a second person, QC charts and the certificate register. Screens from the development version, with demonstration data.

4 October 2026 · Instrument

Introducing the Aura1

A second member of the Aura family: a compact, USB-powered module for temperature, humidity and barometric pressure, with the measurement principles of the Aura2 in a deliberately simple form. Designed for the production of reference materials and calibration gases: next to the balance, GasCatena reads it at every weighing.

3 October 2026 · Company

New website: NexChrom and the Aura2

The new website presents NexChrom, from CDS file to certified result, and the Aura2 ambient sensor. Both are in development; the first release is expected in early 2027. Laboratories that would like a preview, or to take part as a pilot laboratory, are welcome to get in touch.

1 October 2026 · Article

Bayesian statistics and AI in analytical measurement

Why measurement uncertainty is more than a single number, and why correlated errors matter: an article by Erik van der Werff on probability distributions, covariances and the convergence of Bayesian statistics, AI and modern computing.

25 September 2026 · Instrument

Introducing the Aura2

The first member of the Aura family: a stand-alone module that logs temperature, humidity and barometric pressure on its own, day and night, also on battery. Every value is the mean of a series of readings, reported with its standard deviation. Read it from a browser over Wi-Fi or from your own software, without a cloud account.

Descriptions reflect the products as they are being developed and may change before release. See our disclaimer.